Leading Manufacturer of moisture analyzer pgb 1mb, moc-120h electronic moisture balances and moc 63u infrared moisture balance from Vasai Virar.
₹ 85000 / Piece Get Latest Price
| Automation Grade | Automatic |
| Usage/Application | Laboratory |
| Display Type | Digital |
The Moisture Analyzer PGB 1MB is a specific model designed for measuring moisture content in substances using advanced analytical techniques. Here’s an overview of its features, applications, and considerations:
Features and Components:Moisture Measurement Principle: Typically utilizes the principle of loss on drying (LOD) or thermogravimetric analysis (TGA) to determine moisture content. The sample is heated, and the loss in weight as moisture evaporates is measured and analyzed.
Digital Display: Equipped with a digital display screen that shows moisture content readings in percentage (% moisture) or other applicable units. This allows for easy reading and recording of moisture measurements.
Halogen Heating: Often includes a halogen lamp as a heating source for rapid and uniform drying of samples. Halogen heating ensures quick and consistent results across different sample types.
Measurement Range: Offers a broad range of moisture measurement capabilities suitable for applications ranging from low-moisture substances (like pharmaceuticals and chemicals) to high-moisture materials (such as food products).
Temperature Control: Some models feature temperature control features to prevent overheating of samples and ensure accurate moisture determination without affecting sample integrity.
Sample Handling: Designed with a sample pan or tray where the sample is placed for drying. The analyzer calculates moisture content based on the initial and final weights of the sample.
Data Storage and Connectivity: Allows for storage of moisture data and may offer options for connecting to a computer or printer for data transfer and documentation. This facilitates easy record-keeping and analysis of moisture measurements.
User-Friendly Interface: Designed with intuitive controls and menu navigation for easy operation. Some models may feature touchscreen interfaces or simple button controls for user convenience.
Calibration: Requires periodic calibration to maintain accuracy. Calibration standards and procedures are typically provided by the manufacturer and should be followed to ensure reliable moisture measurements.
Quality Control: Used in industries such as food processing, pharmaceuticals, chemicals, and agriculture for ensuring product quality and consistency by monitoring moisture levels.
Research and Development: Essential for studying the moisture content of substances, optimizing formulations, and conducting experiments in laboratories.
Process Control: Employed in manufacturing processes to monitor and control moisture content during production to ensure product quality and performance.
Environmental Monitoring: Used in environmental science and research to analyze moisture content in soil samples, biomass, and other natural materials.
Accurate Measurements: Provides precise moisture content measurements, crucial for quality control and compliance with regulatory standards.
Rapid Analysis: Offers quick results due to advanced analytical techniques and halogen heating technology, allowing for efficient testing and decision-making in production and research environments.
Data Management: Enables easy storage, retrieval, and analysis of moisture data, facilitating documentation and traceability of measurements.
₹ 369000 / Piece Get Latest Price
| Model Name/Number | MOC-120H |
| Usage/Application | Laboratory |
| Brand | Shimadzu |
| Measuring Range | 0 to 120 gm |
| Warranty | 1 Year |
| Operating Temperature | 0-60 Degree Celsius |
The MOC-120H Electronic Moisture Balance is a specific model of moisture balance designed for accurate and precise determination of moisture content in various substances. Here’s an overview of its features, applications, and considerations:
Features and Components:Electronic Measurement: Utilizes electronic sensors and a balance mechanism to measure the weight loss of a sample as it dries, which corresponds to its moisture content.
Digital Display: Equipped with a digital display screen that shows moisture content readings in percentage (% moisture) or other applicable units. This allows for easy reading and recording of moisture measurements.
Halogen Heating: Typically employs a halogen lamp as a heating source for rapid and uniform drying of samples. Halogen heating ensures quick and consistent results across different sample types.
Measurement Range: Offers a wide range of moisture measurement capabilities, suitable for applications ranging from low-moisture substances (like pharmaceuticals and chemicals) to high-moisture materials (such as food products).
Temperature Control: Some models may include temperature control features to prevent overheating of samples and ensure accurate moisture determination without affecting sample integrity.
Sample Handling: Designed with a sample pan or tray where the sample is placed for drying. The balance automatically calculates moisture content based on the initial and final weights of the sample.
Data Storage and Connectivity: Allows for storage of moisture data and may offer options for connecting to a computer or printer for data transfer and documentation. This facilitates easy record-keeping and analysis of moisture measurements.
User-Friendly Interface: Designed with intuitive controls and menu navigation for easy operation. Some models may feature touchscreen interfaces or simple button controls for user convenience.
Calibration: Requires periodic calibration to maintain accuracy. Calibration standards and procedures are typically provided by the manufacturer and should be followed to ensure reliable moisture measurements.
Quality Control: Used in industries such as food processing, pharmaceuticals, chemicals, and agriculture for ensuring product quality and consistency by monitoring moisture levels.
Research and Development: Essential for studying the moisture content of substances, optimizing formulations, and conducting experiments in laboratories.
Process Control: Employed in manufacturing processes to monitor and control moisture content during production to ensure product quality and performance.
Environmental Monitoring: Used in environmental science and research to analyze moisture content in soil samples, biomass, and other natural materials.
Accurate Measurements: Provides precise moisture content measurements, crucial for quality control and compliance with regulatory standards.
Rapid Analysis: Offers quick results due to halogen heating technology, allowing for efficient testing and decision-making in production and research environments.
Data Management: Enables easy storage, retrieval, and analysis of moisture data, facilitating documentation and traceability of measurements.
₹ 120000 / Piece Get Latest Price
| Model Name/Number | MOC 63u |
| Usage/Application | Laboratory |
| Brand | Shimadzu |
| Measuring Range | 0 to 60 gm |
| Warranty | 1 Year |
| Operating Temperature | 0-60 Degree Celsius |
The MOC 63u Infrared Moisture Balance is a specific model designed for measuring moisture content in samples using infrared technology. Here’s an overview of its features, applications, and considerations:
Features and Components:Moisture Measurement Principle: Utilizes infrared heating and detection technology to measure moisture content. Infrared radiation is absorbed by water molecules in the sample, causing them to heat up and release moisture, which is then measured by the balance.
Digital Display: Equipped with a digital display screen that shows moisture content readings in percentage (% moisture) or other applicable units. This allows for easy reading and recording of moisture measurements.
Infrared Heating: Employs infrared lamps or elements as a heating source for drying samples. Infrared heating is efficient and allows for rapid and uniform drying of samples.
Measurement Range: Offers a broad range of moisture measurement capabilities suitable for various applications, including low-moisture substances (like powders and solids) to high-moisture materials (such as pastes and slurries).
Temperature Control: Some models may include temperature control features to maintain consistent heating conditions and prevent overheating of samples during moisture determination.
Sample Handling: Typically includes a sample pan or tray where the sample is placed for drying. The balance calculates moisture content based on the initial and final weights of the sample.
Data Storage and Connectivity: Allows for storage of moisture data and may offer options for connecting to a computer or printer for data transfer and documentation. This facilitates easy record-keeping and analysis of moisture measurements.
User-Friendly Interface: Designed with intuitive controls and menu navigation for easy operation. Some models may feature touchscreen interfaces or simple button controls for user convenience.
Calibration: Requires periodic calibration to maintain accuracy. Calibration standards and procedures are typically provided by the manufacturer and should be followed to ensure reliable moisture measurements.
Quality Control: Used in industries such as food processing, pharmaceuticals, chemicals, and agriculture for ensuring product quality and consistency by monitoring moisture levels.
Research and Development: Essential for studying the moisture content of substances, optimizing formulations, and conducting experiments in laboratories.
Process Control: Employed in manufacturing processes to monitor and control moisture content during production to ensure product quality and performance.
Environmental Monitoring: Used in environmental science and research to analyze moisture content in soil samples, biomass, and other natural materials.
Accurate Measurements: Provides precise moisture content measurements, crucial for quality control and compliance with regulatory standards.
Rapid Analysis: Offers quick results due to infrared heating technology, allowing for efficient testing and decision-making in production and research environments.
Data Management: Enables easy storage, retrieval, and analysis of moisture data, facilitating documentation and traceability of measurements.
Shanni Chaubey (Director)
Analysis Instruments
D-Mart, Shop No. 10, Sai Deep Plaza CHS, Yashwant Viva Township, Palghar
Vasai Virar - 401209, Palghar, Maharashtra, India